AC-MINI-W2
AC Power Supply 12V/2A - North America
Switching wall mount power supply. Output voltage 12V, Output current 2A, Power 24W, Wide range input 90-264V, Plug W2 for use in North America. Output Connector 2.1x5.5, Cable length 1.8 m.
| GENERAL | |
| Voltage DC | 12V |
| Loading | 0 to 0.5A |
| Max Power | 6W |
| Ripple & Noise | 200mV p-p |
| Connector | 2.1 x 5.5 x 11mm |
| INPUT | |
| Voltage | 90 to 264 VAC |
| Frequency | 47 to 63 Hz |
| Current | 0.5A rms@ AC low line input and DC output full load |
| Inrush Surge Current (cold start) | 30/60A max. @ power supply cold start, ambient temperature 25°C @115Vac/230Vac nominal AC input. |
| Leakage current | <0.25 mA Max |
| PROTECTION | |
| Over current/Short protection | The power supply will self-protect any output to ground & auto recovery when abnormal circuit faults remove. An output short circuit is defined as any output impedance less than 0.1Ω |
| Over Voltage | The power supply will be auto recovered when faults remove |
| Input protection | F1 1A/250V Fuse. The power supply shall be protected against power line surges and any abnormal condition |
| No Load protection | The power supply is provided with no load operation to prevent the power supply and system from damage |
| Protection class | II |
| OTHERS | |
| Dielectric Strength (HI-POT) | Primary to Secondary:3000VAC 10mA/60S |
| M.T.B.F | 500,000 Calculated Hours at 25°C, by Telcordia SR-332 |
| Cable Length | 1830mm (6 feet) standard 2 wire cable or as required |
| PLD (power line disturbance) | Line power surge | Line voltage SAG-more info on request |
| Cooling method | Natural Convection Cooling |
| Housing material | PC or PPO |
| Temperature coefficient | <±0.5%/°C |
| OPERATING CONDITIONS | |
| Temperature | 0 to 40°C |
| Humidity | 8 to 90% RH non condensing |
| SAFETY | |
| Standards | CE | cULus | FCC | CB | PSE | BSMI |
| CE-EMC | 2014/30/EU |
| CE-LVD | 2014/35/EU; EN 60950-1:2006+A11+A1+A12+A2 |
| Size and Weight | |
| Shipping Weight | 75 x 34 x 43mm / 50g |